Buying guides · Component selection
Check Zener voltage and current before an RFQ
By VEQORIN · Published
“5.1 V Zener” is a useful starting point, but it does not identify a part to order. Before sending an RFQ, keep the manufacturer's full ordering code. If the code is missing, ask the design owner for the datasheet and the operating conditions instead of choosing the nearest voltage in a catalog.
Check the voltage at its stated current
The Zener voltage, VZ, is specified at a test current, IZT. It is not a promise that the diode will hold the same voltage at every current. The Nexperia Zener application note explains how the operating point changes with Zener current. A Diodes Incorporated datasheet puts the voltage range, IZT, impedance and reverse leakage in separate columns. Read the row for the exact part, including its units and test conditions.
If a design uses only a small bias current, ask the engineer whether the specified voltage and impedance still meet the circuit requirement at that current. Do not infer this from the nominal voltage alone. The same question matters if a proposed replacement has a different test current.
Keep the tolerance and thermal conditions with the MPN
The suffix can distinguish voltage tolerance or package within a manufacturer's family. Nexperia's application note gives examples where a character in its own ordering code marks a tolerance selection; that convention must not be applied to every manufacturer. Send the complete code, not a shortened family name.
Power rating also needs its stated temperature and mounting conditions. The Diodes Incorporated datasheet plots power derating with ambient temperature and gives separate electrical limits. A headline wattage by itself does not confirm a part will survive the intended board conditions. The design owner should check the expected current, resulting dissipation and temperature against the exact datasheet.
A short RFQ that avoids a second round of questions
Include the manufacturer and complete MPN, required quantity, package or approved footprint, and the relevant datasheet revision. If the exact part is unavailable, add the required VZ range at its test current, allowed tolerance, expected operating current, power and temperature limits. State whether the request is for an exact part or an engineer-reviewed alternative. A distributor can help source against those requirements; it cannot approve electrical or board compatibility from a similar voltage label.
For a transient-protection part, first check whether the design calls for a Zener regulator or a TVS diode: the TVS datasheet guide covers different ratings. Then send the complete MPN and the relevant conditions through the RFQ page.